BCQYL - FORMSET DRESSER DIAMOND (NICKEL COATED)

Product Identification

Product ID:FORMSET DRESSER DIAMOND (NICKEL COATED)
MSDS Date:11/12/1985
FSC:3455
NIIN:00N008759
MSDS Number: BCQYL

Responsible Party
GENERAL ELECTRIC CO., SPECIALTY MATERIALS DEPT.
6325 HUNTLEY ROAD
WORTHINGTON, OH 43085

Emergency Phone: 614-438-2205

Cage: 08036

Contractor
GENERAL ELECTRIC CO,SPECIALTY MATERIALS DPTMNT
WORTHINGTON, OH 43085

Telephone: 614-438-2205

Cage: 08036

Ingredients

GRAPHITE, SYNTHETIC

CAS: 7440-44-0

RTECS: FF5250100

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 2 MG/M3 TDUST; 9293


COBALT (SARA III)

CAS: 7440-48-4

RTECS: GF8750000

Fraction By Weight: <10%

OSHA PEL 0.1 MG/M3;AS CO

ACGIH TLV: 0.05 MG/M3;DUST 9293


NICKEL (SARA III)

CAS: 7440-02-0

RTECS: QR5950000

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9192


PHOSPHOROUS (YELLOW) (SARA III)

CAS: 7723-14-0

RTECS: TH3500000

OSHA PEL 0.1 MG/M3

ACGIH TLV: 0.1 MG/M3; 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB

Hazards

LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INH:POTENTIAL FOR CAUSING TRANSIENT OR
PERMANENT RESPIRATORY DISEASE (PROBABLY FROM COBALT DUST).AIRBORNE
NICKEL DUSTS ARE REGARDED AS CARCINOGENS.INGEST:IT HAS BEEN
SUGGESTED THAT COBALT HAS POTENTIA L FOR CAUSING BLOOD,HEART, AND
ORGAN PROBLEMS.
Explanation of Carcinogenicity:LIMITED EVIDENCE FOR CARCINOGENICITY IN
HUMANS FOR NICKEL & SOME NICKEL COMPOUNDS (IARC 1982) (SEE SUPP
DATA)
Effects of Overexposure:INHAL:DUST FROM GRINDING CAN CAUSE THROAT &
NOSE IRRITATION.SKIN:CAN CAUSE IRRITATION OR ALLERGIC SKIN RASH DUE
TO COBALT SENSITIZATION A FORM OF DERATITIS CAN RESULT FROM SKIN
EXPOS TO NICKEL.EYE:CAN CAUSE IRRIT.
Medical Cond Aggravated by Exposure:N/K

First Aid

First Aid:INH:REMOVE FROM EXPOS.INGEST:IF SUSTANTIAL QUANTITIES ARE
INGESTED,DILUTE W/ LARGE AMT OF WATER.INDUCE VOMIT.SKIN:WASH W/
SOAP & WATER.EYE:FLUSH EYES W/ WATER FOR AT LEAST 15 MINUTES.FOR
ALL ABOVE CAS ES,SEEK MED ATTN.

Fire Fighting

Flash Point:N/K
Extinguishing Media:N/K
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:SWEEP UP & DISPOSE INERT SOLID.
Neutralizing Agent:N/K

Handling

Handling and Storage Precautions:HANDLE W/ ADEQUATE VENTILATION FOR
NUSIANCE DUST.
Other Precautions:ADEQUATE EXHAUST.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL & GENERAL MECHANICAL NECESSARY TO KEEP AIR CONC BELOW
TLV .
Protective Gloves:WHEN CONT W/ DUST OR MIST IS LIKELY.
Eye Protection:CHEM WORKERS GOGGLES (SEE SUPP DATA)
Other Protective Equipment:N/K
Work Hygienic Practices:N/K
Supplemental Safety and Health
EYE PROT:WEAR GOGGLES WHEN OPERATING GRINDING,CUTTING,OR DRILL
EQUIP.CARCINOGENICITY:ACGIH:HUMAN CARCINOGEN (1987).PHYSICAL
PROPERTIES:BP:COATING-4892F,2700C;MP-APPROX 2552F,1400C;VP:NI-1MM @
1810C.

Chemical Properties

Boiling Pt:B.P. Text:SUPP DATA
Melt/Freeze Pt:M.P/F.P Text:SUPP DATA
Decomp Temp:Decomp Text:N/K
Vapor Pres:SUPP DATA
Solubility in Water:INSOLUBLE
Appearance and Odor:METAL COATED ARTICLES.SILVER GRAY;NO ODOR
Percent Volatiles by Volume:NONE

Stability

Stability Indicator/Materials to Avoid:YES
N/K
Stability Condition to Avoid:N/K
Hazardous Decomposition Products:N/K

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE W/ FEDERAL,STATE
& LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.